Flowmeter with measuring section and flange connection to DIN EN 1092-1, DN 15 to DN 50, calorimetric, up to 16 bar - Riegler
Calorimetric flowmeters with measuring section and flange connection to DIN EN 1092-1 in nominal sizes DN 15 to DN 50, for consumption, leakage and energy efficiency measurements on compressed air and neutral gases. Measuring range 0.2 m³/h to 90 m³/h at DN 15 and 2.0 m³/h to 1195 m³/h at DN 50, operating pressure up to 16 bar, supply 24 V DC. Choose the nominal size in the variant selection.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Calorimetric flowmeters with measuring section and flange connection to DIN EN 1092-1 in nominal sizes DN 15 to DN 50, for consumption, leakage and energy efficiency measurements on compressed air and neutral gases.
Measuring range 0.2 m³/h to 90 m³/h at DN 15 and 2.0 m³/h to 1195 m³/h at DN 50, operating pressure up to 16 bar, supply 24 V DC.
Benefits
- DN 15 to DN 50 with defined measuring section for high accuracy
- Backlit display: current and total consumption
- analogue 4 - 20 mA, pulse output (galvanically separated)
- No pressure and temperature compensation required
Applications
- System monitoring of flow and consumption changes
- Leakage and energy efficiency measurements
Technical data
| Temperature range | -30 to 80 °C |
|---|---|
| Operating pressure | up to 16 bar |
| Flow rate output | Analogue 4 - 20 mA, pulse output (galvanically separated) |
| Dimension H1 | 165.7 mm |
| Measuring system | Calorimetric measurement |
| Medium | Compressed air, neutral gases |
| Operating voltage | 24 V DC |
| Display | Background lighting |
| Flange | DIN EN 1092-1 |
| Nominal size DN | DN 15 to DN 50 |
| Tube I.D. | 16.1 to 53.1 mm |
| Flow measuring range (min., depending on variant) | 0.2 to 2 m³/h |
| Flow measuring range (max., depending on variant) | 90 to 1195 m³/h |
| Dimension L | 300 to 475 mm |
| Flange-Ø D | 95 to 165 mm |
| Pitch circle Ø K | 65 to 125 mm |
| No. of bolt holes | 4 x 14, 4 x 18 |
| Manufacturer | Riegler |
| GPSR Herstellerdaten | Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Norm | DIN EN 1092-1 |
| Betriebsdruck max [bar] | 16 |
| Temperaturbereich | -30-80 °C |
| Temperature (max.) | 80 |
Downloads
Datasheet
User Manual
Accessories
Wall power supply 100 to 240 V AC to 24 V DC, 5-pole M12x1, for flow meters, type SNT-230/24 - Riegler 135865
Item RGL-135865Connection cable for flow meters, to hand-held unit, approx. 5 m, preassembled, type DL200-AL5 - Riegler 135866
Item RGL-135866Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.