Images are examples, some edited with AI. The technical data are authoritative. AI notice
IO-Link master for CPX-AP-A, IO-Link protocol, 4 IO-Link ports, 24 V DC CPX-AP-A-4IOL-M12 - Festo 8129114
The Festo IO-Link master CPX-AP-A-4IOL-M12 connects IO-Link devices to the CPX-AP-A system. The data sheet lists IO-Link protocol, 4 IO-Link ports and nominal operating voltage 24 V DC. It also offers power failure bridging 10 ms and reverse polarity protection.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The IO-Link master CPX-AP-A-4IOL-M12 connects IO-Link devices to the CPX-AP-A system. The main data are IO-Link protocol and 4 IO-Link ports.
Advantages
- Fieldbus connection via IO-Link
- 4 IO-Link ports for sensors and actuators
- Nominal operating voltage 24 V DC
- Power failure bridging 10 ms
- Integrated reverse polarity protection
- Internal cycle time < 1 ms
Application
CPX-AP-A-4IOL-M12 is used to build and extend automation solutions based on the CPX-AP-A system.
Technical data
| Type | CPX-AP-A-4IOL-M12 |
|---|---|
| Festo part number | 8129114 |
| Protocol | IO-Link |
| Dimensions (W x L x H) | 50.1 mm x 107.3 mm x 57.5 mm |
| Grid dimension | 50.1 mm |
| Type of mounting | Screw-clamped |
| Product weight | 90 g |
| Mounting position | Any |
| Ambient temperature | -20 to 50 °C |
| Note on ambient temperature | Observe ambient temperature derating according to IEC 61131-2:2017 |
| Storage temperature | -20 to 70 °C |
| Relative air humidity | 5 - 95%, Non-condensing |
| Nominal altitude of use | ≤ 2000 m ASL (> 79.5 kPa) |
| Max. installation height | 3500 m |
| Note on max. installation height | Observe ambient temperature derating according to IEC 61131-2:2017 |
| Corrosion resistance class CRC | 1 - Low corrosion stress |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Note on vibration resistance | Transport application test with severity class 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Note on shock resistance | 30 g/11 ms to EN 60068-2-27, SG1 on DIN rail, SG2 on direct mounting, Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Protection class | III |
| Pollution degree | 2 |
| Overvoltage category | II |
| Max. cable length | 20 m with IO-Link operation |
| LABS (PWIS) conformity | VDMA24364-B2-L |
| Fire test material | UL94 V-0 (housing) |
| Note on materials | RoHS compliant, Free of halogen, Free of phosphoric acid ester |
| Material cover | Reinforced PBT |
| Material screws | Nickel-plated steel |
| Material o-ring | Fluoro rubber |
| Diagnostics via LED | Diagnostics per channel, Diagnostics per module, Load power supply, Status per channel, Status per module |
| Diagnostics per internal communication | IO-Link event, Short circuit/overload in sensor supply, Electronics/sensors overvoltage, Load overvoltage, Electronics/sensors undervoltage, Load undervoltage |
| Max. address volume, inputs | 33 byte |
| Max. address volume, outputs | 33 byte |
| Module parameters | Configuration of voltage monitoring load supply PL |
| Channel parameters | Activation diagnostics for IO-Link device lost, Port mode, Target DeviceID, Target VendorID, Target cycle time |
| Internal cycle time | < 1 ms |
| Configuration support | IODD file |
| Communication interface, protocol | AP |
| Note regarding operating voltage | SELV/PELV fixed power supplies required, Note the voltage drop |
| Note on nominal operating voltage DC | Protected Extra-Low-Voltage to IEC 60204-1 |
| Nominal operating voltage DC of load | 24 V |
| Permissible voltage fluctuation of load | ± 25 % |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25 % |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 40 mA |
| Intrinsic current consumption at nominal operating voltage load | Typically 4 mA |
| Power failure bridging | 10 ms |
| Potential separation between the supply voltages electronics/sensor technology and load/valves | Yes |
| Reverse polarity protection | Yes |
| Fuse protection of inputs (short circuit) | Internal electronic fuse per module |
| Max. residual current of inputs per module | 2 A |
| Behaviour after end of overload of the outputs | No automatic return |
| Max. residual current outputs per module | 4 A |
| Electrical isolation of outputs between channel - internal communication | Yes |
| Max. power supply per channel | 2.1 A (50 W lamp load), per channel pair |
| Electrical connection for IO-Link, connection type | 4x socket |
| Electrical connection for IO-Link, connection technology | M12x1, A-coded to EN 61076-2-101 |
| Electrical connection for IO-Link, number of pins/wires | 5 |
| IO-Link, communication | C/Q LED green |
| IO-Link, Number of ports | 4 |
| IO-Link, Port class | B |
| IO-Link, Protocol version | Master V 1.1 |
| IO-Link, communication mode | DI, COM1. COM2. COM3., Configurable via software |
| IO-Link, Process data length OUT | Can be parameterised 8 - 128 bytes |
| IO-Link, Process data length IN | Can be parameterised 12 - 132 bytes |
| IO-Link, Min. cycle time | Dependent on minimum supported cycle time of the connected IO-Link device |
| Weight | 0.1 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPX-AP-A-4IOL-M12 |
| EAN | 4052568611620 |
| Zolltarifnummer | 85389099 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Operating voltage | 24 V DC |
| Temperaturbereich | -20-50 °C |
| Temperature (max.) | 50 |
Downloads
Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.