Solenoid valve 2x3/2 closed monostable, ISO 5599-2, width 52 mm VSVA-B-T32C-AZ-D2-1T1L - Festo 8034991
The standard valve VSVA-B-T32C-AZ-D2-1T1L works as a double 3/2-way valve, both closed, delivers up to 2400 l/min nominal flow and mounts on sub-base size 2 to ISO 5599-2. Operating pressure 3 to 10 bar, 24 V DC coil with 4.6 W, electrical connection plug-in to ISO 5599-2.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Double 3/2-way valve, both closed VSVA-B-T32C-AZ-D2-1T1L by Festo: 2400 l/min nominal flow, width 52 mm, designed to ISO 5599-2.
Benefits
- Standardised hole pattern: Sub-base size 2 to ISO 5599-2, so the 2x3/2 valve can be replaced without changing the sub-base.
- Flow rate: 2400 l/min nominal flow, 2600 l/min on individual sub-base, 2400 l/min pneumatically interlinked.
- Plugged electrically: plug-in to ISO 5599-2, the 4.6 W coil is contacted via the sub-base when mounted.
- Pressure range: 3 to 10 bar.
- Degree of protection: IP65, NEMA 4.
- Manual override: covered.
Application
Two independent 3/2-way functions in one housing, closed at rest, for example for two single-acting actuators. The operating medium is compressed air to ISO 8573-1:2010 [7:4:4], permissible ambient temperature -5 to 50 °C, product weight 740 g.
Technical data
| Type | VSVA-B-T32C-AZ-D2-1T1L |
|---|---|
| Festo part number | 8034991 |
| Valve function | 2x3/2 closed monostable |
| Type of actuation | Electrical |
| Construction width | 52 mm |
| Standard nominal flow rate | 2400 l/min |
| Operating pressure | 3 to 10 bar |
| Design | Piston gate valve |
| Approval | C-Tick, c CSA us (OL), c UL us - Recognised (Oil) |
| Degree of protection | IP65, NEMA 4 |
| Exhaust-air function | Can be throttled, Via throttle plate, Via individual sub-base |
| Sealing principle | Soft |
| Mounting position | Any |
| Manual override | Covered |
| Type of piloting | Piloted |
| Pilot air supply | External |
| Flow direction | Non-reversible |
| Signal status display | LED |
| Pilot pressure | 3 to 10 bar |
| Flow rate of valve | 3000 l/min |
| Flow rate of valve on individual sub-base | 2600 l/min |
| Flow rate of pneumatically interlinked valve | 2400 l/min |
| Switching time off | 35 ms |
| Switching time on | 20 ms |
| Duty cycle | 100 % |
| Max. positive test pulse with 0 signal | 1000 µs |
| Max. negative test pulse with 1 signal | 3500 µs |
| Characteristic coil data | 24 V DC: 4.6 W |
| Surge resistance | 2.5 kV |
| Degree of pollution | 3 |
| Permissible voltage fluctuations | ± 10 % |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) |
| Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| Relative air humidity | 0 - 90% |
| Ambient temperature | -5 to 50 °C |
| Product weight | 740 g |
| Electrical connection | Plug-in, to ISO 5599-2 |
| Type of mounting | On sub-base |
| Auxiliary pilot air port 12/14 | Sub-base size 2 to ISO 5599-2 |
| Pilot exhaust port 82/84 | Optional:, Ducted, Not ducted according to standard |
| Pneumatic connection, port 1 | Sub-base size 2 to ISO 5599-2 |
| Pneumatic connection, port 2 | Sub-base size 2 to ISO 5599-2 |
| Pneumatic connection, port 3 | Sub-base size 2 to ISO 5599-2 |
| Pneumatic connection, port 4 | Sub-base size 2 to ISO 5599-2 |
| Pneumatic connection, port 5 | Sub-base size 2 to ISO 5599-2 |
| Note on materials | RoHS compliant |
| Material seals | FKM, HNBR, NBR |
| Material housing | PA, Die-cast aluminium |
| Material screws | Galvanised steel |
| Nominal pick-up current per solenoid coil | 165 mA to 30 ms |
| CE mark (see declaration of conformity) | To EU EMC Directive |
| Media temperature | -5 to 50 °C |
| Grid dimension | 59 mm |
| Conforms to standard | ISO 5599-2 |
| Nominal current with current reduction | 35 mA after 30 ms |
| Weight | 0.75 kg |
| Manufacturer | Festo |
| Hersteller-Nr | VSVA-B-T32C-AZ-D2-1T1L |
| EAN | 4052568284572 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Aluminium |
| Seal material | FKM, HNBR, NBR |
| Medium | Compressed air |
| Function | 2x3/2 closed monostable |
| Flow rate [l/min] | 2400 |
| Actuation type | Electrical |
| Norm | ISO 5599-2 |
| Operating conditions | EN 60068-2-27, EN 60068-2-6, ISO 8573-1 |
| Operating voltage | 24 V DC |
| Series | VSVA |
| Betriebsdruck max [bar] | 10 |
| Protection rating | IP65 |
| Temperature (max.) | 50 |
Downloads
Accessories
Solenoid valve 2x3/2 closed monostable, ISO 15407-2, width 18 mm VSVA-B-T32C-AZ-A2-1T1L - Festo 8033480
Item FES-8033480Plug-in solenoid valve 2x 3/2 closed, monostable, ISO 15407-2 26 mm, 24 V DC VSVA-B-T32C-AZ-A1-1T1L - Festo 8033059
Item FES-8033059Solenoid valve 2x3/2 closed monostable, ISO 5599-2, width 52 mm VSVA-B-T32C-AZH-D2-1T1L - Festo 8034976
Item FES-8034976Solenoid valve 2x3/2 closed monostable, ISO 5599-2, width 52 mm VSVA-B-T32C-AZTR-D2-1T1L - Festo 8034961
Item FES-8034961Solenoid valve 2x3/2 closed monostable, ISO 5599-2, width 42 mm VSVA-B-T32C-AZH-D1-1T1L - Festo 8034799
Item FES-8034799Alternatives
Plug-in solenoid valve 5/3 mid-position pressurised, ISO 5599-2 size 2, 24 V DC VSVA-B-P53U-ZD-D2-1T1L - Festo 560822
Item FES-560822Plug-in solenoid valve 5/2 bistable, ISO 5599-2 size 2, 24 V DC VSVA-B-B52-ZD-D2-1T1L - Festo 560818
Item FES-560818Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.