Pressure sensor 0 to 6 bar, 2x PNP/NPN, IO-Link, with display SPAU-P6R-W-G18FD-L-PNLK-PNVBA - Festo 8001233
Measuring range 0 to 6 bar: the pressure sensor SPAU-P6R-W-G18FD-L-PNLK-PNVBA measures relative pressure and switches via 2 switching outputs, PNP/NPN switchable, plus analogue output 0 to 10 V, 4 to 20 mA or 1 to 5 V. It connects pneumatically via G1/8 port and electrically via M8x1 plug (4-pin).
Available
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
Designed for pressures of 0 to 6 bar, the Festo pressure sensor SPAU-P6R-W-G18FD-L-PNLK-PNVBA measures relative pressure and switches via 2 switching outputs, PNP/NPN switchable, plus analogue output 0 to 10 V, 4 to 20 mA or 1 to 5 V. Operating medium for SPAU-P6R-W-G18FD-L-PNLK-PNVBA: compressed air and inert gases, medium temperature 0 to 50 °C.
Benefits
- Measuring range 0 to 6 bar, overload range up to 15 bar
- G1/8 port, electrical: M8x1 plug (4-pin)
- Degree of protection IP65, IP67, ambient temperature 0 to 50 °C
- Accuracy 1.5 %FS, repeatability ± 0.3 %FS
- 2 switching outputs, PNP/NPN switchable, N/C or N/O switchable, output current up to 100 mA
- Illuminated LCD, setting via teach-in, display and keys or IO-Link
Application
The device is used to check system pressure, clamping pressure or leaks on pneumatic installations. The mounting position is freely selectable, mounting is with a wall/surface bracket.
Technical data
| Type | SPAU-P6R-W-G18FD-L-PNLK-PNVBA |
|---|---|
| Approval | RCM, c UL us - Listed (OL) |
| CE marking (see declaration of conformity) | To EU EMC Directive, to EU RoHS Directive |
| KC mark | KC EMC |
| Note on materials | RoHS-compliant |
| Measured variable | Relative pressure |
| Measuring method | Piezoresistive pressure sensor |
| Pressure measuring range initial value | 0 bar |
| Pressure measuring range full scale value | 6 bar |
| Overload range | 15 bar |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4], inert gases |
| Note on operating and pilot medium | Lubricated operation possible |
| Medium temperature | 0 to 50 °C |
| Ambient temperature | 0 to 50 °C |
| Resolution of analogue-digital converter | 12 Bit |
| Accuracy FS | 1.5 %FS |
| Repeatability in ± %FS | 0.3 %FS |
| Temperature coefficient in ± %FS/K | 0.05 %FS/K |
| Switching output | 2x PNP or 2x NPN, switchable |
| Switching function | Freely programmable |
| Switching element function | N/C or N/O contact, switchable |
| Maximum output current | 100 mA |
| Analogue output | 0 - 10 V, 4 - 20 mA, 1 - 5 V |
| Rise time | 3 ms |
| Maximum load resistance current output | 500 Ohm |
| Minimum load resistance voltage output | 10 kOhm |
| Short circuit protection | Yes |
| Protocol | IO-Link |
| IO-Link, protocol | Device V 1.1 |
| IO-Link, Profile | Smart Sensor Profile |
| IO-Link, Function classes | Teach channel, diagnosis, identification, binary data channel (BDC), process data variable (PDV) |
| IO-Link, communication mode | COM2 (38.4 kBaud) |
| IO-Link, SIO-Mode support | Yes |
| IO-Link, port type | A |
| IO-Link, Process data length OUT | 0 Byte |
| IO-Link, Process data length IN | 2 Byte |
| IO-Link, Process data content IN | 14 bit PDV (pressure measured value), 2 bit BDC (pressure monitoring) |
| IO-Link, Min. cycle time | 3 ms |
| IO-Link, Data storage required | 500 Byte |
| Operating voltage range DC | 20 to 30 V |
| Reverse polarity protection | For all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connector system | M8x1, A-coded to EN 61076-2-104 |
| Electrical connection 1, number of connections/cores | 4 |
| Type of mounting | Via wall/surface bracket |
| Mounting position | Any |
| Pneumatic connection | G1/8 |
| Product weight | 70 g |
| Display type | Illuminated LCD |
| Displayable unit(s) | MPa, bar, inchH2O, inchHg, kPa, kgf/cm², mmHg, psi |
| Setting options | IO-Link, Teach-in, via display and keys |
| Tamper protection | IO-Link, PIN code |
| Threshold setting range | 0 to 100 % |
| Hysteresis setting range | 0 to 90 % |
| Degree of protection | IP65, IP67 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| Weight | 0.095 kg |
| Manufacturer | Festo |
| Hersteller-Nr | SPAU-P6R-W-G18FD-L-PNLK-PNVBA# |
| EAN | 4052568277109 |
| Zolltarifnummer | 90262020 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Thread | G 1/8 |
| Measuring range max. [bar] | 6 |
| Medium | Compressed air, neutral gases |
| Norm | DIN EN 61076-2-104 |
| Operating conditions | ISO 8573-1 |
| Series | SPAU |
| Protection rating | IP65 |
| Temperaturbereich | 0-50 °C |
| Temperature (max.) | 50 |
Downloads
Accessories
Connecting cable M8x1, 3-pin, 3-wire, socket, angled, open end 2.5 m SIM-M8-3WD-2,5-PSL-PU - Festo 159424
Item FES-159424Pressure sensor 0 to 2 bar, 2x PNP/NPN, IO-Link, with display SPAU-P2R-W-G18FD-L-PNLK-PNVBA - Festo 8001232
Item FES-8001232Pressure sensor 0 to 10 bar, 2x PNP/NPN, IO-Link, with display SPAU-P10R-W-G18FD-L-PNLK - Festo 8001230
Item FES-8001230Pressure sensor 0 to 10 bar, 2x PNP/NPN, IO-Link, with display SPAU-P10R-W-Q4D-L-PNLK-PNVBA - Festo 8001236
Item FES-8001236Pressure sensor 0 to 10 bar, 2x PNP/NPN, IO-Link, with display SPAU-P10R-F-Q6-L-PNLK-PNVBA - Festo 8001225
Item FES-8001225Pressure sensor 0 to 10 bar, 2x PNP/NPN, IO-Link, with display SPAU-P10R-F-Q4-L-PNLK-PNVBA - Festo 8001224
Item FES-8001224Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.