Pressure sensor -1 to 1 bar, 2x PNP/NPN, IO-Link, with display SPAN-B2R-G18M-PNLK-PNVBA-L1 - Festo 8035534
Designed for pressures of -1 to 1 bar, the pressure sensor SPAN-B2R-G18M-PNLK-PNVBA-L1 monitors relative pressure and switches via 2 switching outputs, PNP/NPN switchable, plus analogue output 0 to 10 V, 4 to 20 mA or 1 to 5 V. Illuminated LCD, setting via teach-in, display and keys or IO-Link.
Available
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The Festo pressure sensor SPAN-B2R-G18M-PNLK-PNVBA-L1 monitors relative pressure in the range -1 to 1 bar and switches via 2 switching outputs, PNP/NPN switchable, plus analogue output 0 to 10 V, 4 to 20 mA or 1 to 5 V. Operating medium for SPAN-B2R-G18M-PNLK-PNVBA-L1: compressed air and inert gases, medium temperature 0 to 50 °C.
Benefits
- Measuring range -1 to 1 bar, overload range up to 5 bar
- Accuracy 1.5 %FS, repeatability ± 0.3 %FS
- 2 switching outputs, PNP/NPN switchable, N/C or N/O switchable, output current up to 100 mA
- Analogue output 0 to 10 V, 4 to 20 mA or 1 to 5 V, IO-Link (Device V 1.1) for parameterisation and diagnostics
- Degree of protection IP40, ambient temperature 0 to 50 °C
- Male thread G1/8, female thread M5, electrical: plug connection (4-pin)
Application
The measuring range covers vacuum and positive pressure, making the device suitable for circuits with changing pressure conditions. Mounting is in a front panel, with a wall/surface bracket or via the thread, in any mounting position.
Technical data
| Type | SPAN-B2R-G18M-PNLK-PNVBA-L1 |
|---|---|
| Approval | RCM, c UL us - Listed (OL) |
| CE marking (see declaration of conformity) | To EU EMC Directive, to EU RoHS Directive |
| KC mark | KC EMC |
| Certificate issuing authority | UL E322346 |
| Note on materials | RoHS-compliant |
| Measured variable | Relative pressure |
| Measuring method | Piezoresistive pressure sensor |
| Pressure measuring range initial value | -1 bar |
| Pressure measuring range full scale value | 1 bar |
| Overload range | 5 bar |
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4], inert gases |
| Note on operating and pilot medium | Lubricated operation possible |
| Medium temperature | 0 to 50 °C |
| Ambient temperature | 0 to 50 °C |
| Accuracy FS | 1.5 %FS |
| Repeatability in ± %FS | 0.3 %FS |
| Temperature coefficient in ± %FS/K | 0.05 %FS/K |
| Switching output | 2x PNP or 2x NPN, switchable |
| Switching function | Window comparator, threshold comparator, auto difference monitoring |
| Switching element function | N/C or N/O contact, switchable |
| Maximum output current | 100 mA |
| Analogue output | 0 - 10 V, 4 - 20 mA, 1 - 5 V |
| Maximum load resistance current output | 500 Ohm |
| Minimum load resistance voltage output | 20 kOhm |
| Short circuit protection | Yes |
| Protocol | IO-Link |
| IO-Link, protocol | Device V 1.1 |
| IO-Link, Profile | Smart Sensor Profile |
| IO-Link, Function classes | Teach channel, diagnosis, identification, binary data channel (BDC), process data variable (PDV) |
| IO-Link, communication mode | COM2 (38.4 kBaud) |
| IO-Link, SIO-Mode support | Yes |
| IO-Link, port type | A |
| IO-Link, Process data length OUT | 0 Byte |
| IO-Link, Process data length IN | 2 Byte |
| IO-Link, Process data content IN | 14 bit PDV (pressure measured value), 2 bit BDC (pressure monitoring) |
| IO-Link, Min. cycle time | 3 ms |
| IO-Link, Data storage required | 500 Byte |
| Operating voltage range DC | 15 to 30 V |
| Reverse polarity protection | For all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connector system | Connection pattern L1J |
| Electrical connection 1, number of connections/cores | 4 |
| Type of mounting | Front panel mounting, via wall/surface bracket, with thread |
| Mounting position | Any |
| Pneumatic connection | Male thread G1/8, female thread M5 |
| Product weight | 46 g |
| Material housing | Reinforced PA |
| Material in contact with the medium | Fluoro rubber, NBR, reinforced PA, brass, nickel-plated |
| Display type | Illuminated LCD |
| Displayable unit(s) | mmHg, psi, MPa, bar, inchH2O, inchHg, kPa, kgf/cm², mbar |
| Setting options | IO-Link, Teach-in, via display and keys |
| Tamper protection | IO-Link, PIN code |
| Threshold setting range | 0 to 100 % |
| Hysteresis setting range | 0 to 90 % |
| Degree of protection | IP40 |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress |
| Weight | 0.05 kg |
| Manufacturer | Festo |
| Hersteller-Nr | SPAN-B2R-G18M-PNLK-PNVBA-L1 |
| EAN | 4052568284749 |
| Zolltarifnummer | 90262020 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Polyamide (PA) |
| Thread | G 1/8 |
| Measuring range max. [bar] | 1 |
| Medium | Compressed air, neutral gases |
| Operating conditions | ISO 8573-1 |
| Series | SPAN |
| Protection rating | IP40 |
| Temperaturbereich | 0-50 °C |
| Temperature (max.) | 50 |
Downloads
Accessories
Connecting cable M8x1, 3-pin, 3-wire, socket, angled, open end 2.5 m SIM-M8-3WD-2,5-PSL-PU - Festo 159424
Item FES-159424Pressure sensor -1 to 1 bar, 2x PNP/NPN, with display SPAN-B2R-G18M-PN-PN-L1 - Festo 8035545
Item FES-8035545Pressure sensor -1 to 1 bar, 2x PNP/NPN, IO-Link, with display SPAN-B2R-R18M-PNLK-PNVBA-L1 - Festo 8035537
Item FES-8035537Pressure sensor -1 to 1 bar, 2x PNP/NPN, IO-Link, with display SPAN-B2R-M5F-PNLK-PNVBA-L1 - Festo 8035540
Item FES-8035540Pressure sensor -1 to 1 bar, 2x PNP/NPN, IO-Link, with display SPAN-B2R-Q4-PNLK-PNVBA-L1 - Festo 8035542
Item FES-8035542Pressure sensor -1 to 1 bar, 2x PNP/NPN, with display SPAN-B2R-R18M-PN-PN-L1 - Festo 8035548
Item FES-8035548Pressure sensor -1 to 1 bar, 2x PNP/NPN, with display SPAN-B2R-M5F-PN-PN-L1 - Festo 8035551
Item FES-8035551Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.