Images are examples, some edited with AI. The technical data are authoritative. AI notice
Bus node PROFINET IRT, PROFINET RT IP65/IP67 CPX-M-FB35 - Festo 548749
The bus node CPX-M-FB35 from Festo links the terminal to the control level. Decisive are protocol PROFINET IRT, PROFINET RT, baud rate 100 Mbit/s and address volume 64 Byte inputs and 64 Byte outputs.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The bus node CPX-M-FB35 links the terminal to the control level. Decisive are protocol PROFINET IRT, PROFINET RT, baud rate 100 Mbit/s and address volume 64 Byte inputs and 64 Byte outputs.
Your benefits
- Protocol PROFINET IRT, PROFINET RT
- Fieldbus interface 2x SCRJ push-pull socket, AIDA
- Baud rate 100 Mbit/s
- Address volume 64 Byte inputs and 64 Byte outputs
- Nominal operating voltage 24 V DC for control from standard controllers
- Degree of protection IP65/IP67, dust-tight and protected against temporary immersion
Use
One communication connection via CPX-M-FB35 replaces individual wiring of many valves and signals. CPX-M-FB35 allows valve terminals and I/Os to be controlled via a single line.
Technical data
| Order code | CPX-M-FB35 |
|---|---|
| Festo part number | 548749 |
| Dimensions (W x L x H) | 50 mm x 107 mm x 80 mm, (Incl. linking block) |
| Parameterisation | System parameters, Fail-safe response, Diagnostic behaviour, Forcing of channels, Signal setup |
| Additional functions | Fast start up (FSU), Acyclical data access via Fieldbus, Acyclical data access via Ethernet, Start-up parameterisation in text via field bus, System status can be shown from process dat, Additional diagnosis interface for control panel, Channel related diagnosis via fieldbus |
| Operator controls | DIL switch, Optional storage card |
| Operational voltage range DC | 18 to 30 V |
| Internal current consumption, operating voltage | Type 150 mA |
| Nominal operating voltage DC | 24 V |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| Storage temperature | -20 to 70 °C |
| Degree of protection | IP65, IP67 |
| Ambient temperature | -5 to 50 °C |
| Product weight | 280.0 g |
| Max. address volume outputs | 64 Byte |
| Max. address volume inputs | 64 Byte |
| Protocol | PROFINET IRT, PROFINET RT |
| Note on materials | RoHS compliant |
| Material housing | Die-cast aluminium |
| Field bus interface | 2x SCRJ push-pull socket, AIDA |
| Device-specific diagnostics | Undervoltage modules, Diagnostic memory, Channel and module-oriented diagnostics |
| Configuration support | GSDML file |
| Baud rate | 100 Mbit/s |
| LED display, bus-specific | M/P: Maintenance/PROFIenergy, NF: Network error, TP1: Network active port 1, TP2: Network active port 2 |
| LED display, product-specific | PL: Load supply, SF: System error, M: Modify, parameterisation, PS: Electronics supply, sensor supply |
| Weight | 0.36 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPX-M-FB35 |
| EAN | 4052568190132 |
| Zolltarifnummer | 85176200 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Aluminium |
| Housing material | Die-cast aluminium |
| Operating voltage | 24 V DC |
| Series | CPX |
| Protection rating | IP65 |
| Temperature (max.) | 50 |