Images are examples, some edited with AI. The technical data are authoritative. AI notice

Electrical interface for CPX terminal, IO-Link protocol, 2 IO-Link ports, 24 V DC CPX-CTEL-2-M12-5POL-LK - Festo 2900543

Festo ✓ Original product Brand new

The electrical interface CPX-CTEL-2-M12-5POL-LK is a genuine Festo part for the CPX terminal. The data sheet lists IO-Link protocol, 2 IO-Link ports and nominal operating voltage 24 V DC. It also offers power failure bridging 10 ms and IP65/IP67 protection.

Net
€309.88
excl. VAT
Item FES-2900543
Manufacturer no. CPX-CTEL-2-M12-5POL-LK

Available

Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

The electrical interface CPX-CTEL-2-M12-5POL-LK is a genuine Festo part for the CPX terminal. The key selection criteria are IO-Link protocol and 2 IO-Link ports.

Advantages

  • Fieldbus connection via IO-Link
  • 2 IO-Link ports for sensors and actuators
  • Nominal operating voltage 24 V DC
  • Power failure bridging 10 ms
  • IP65/IP67 protection for mounting directly on the machine
  • Suitable for ambient temperatures of -5 to 50 °C

Application

CPX-CTEL-2-M12-5POL-LK is used when designing, extending and maintaining installations with the CPX terminal.

Technical data

TypeCPX-CTEL-2-M12-5POL-LK
Festo part number2900543
SeriesCPX
Dimensions (W x L x H)50 mm x 107 mm x 55 mm, (Incl. linking block)
DiagnosisUnterspannung, Kommunikationsfehler, Kurzschluss Module, Modulorientierte Diagnose
ParameterisationDiagnostic behaviour, fail-safe per channel, forcing per channel, idle mode per channel, module parameters
Operator controlsDIL switch
LED displayPL: Load supply, PS: Electronic supply, sensor supply, Collective diagnosis, X1: System status IO link port 1, X1: System status IO link port 2
Operational voltage range DC18 to 30 V
Internal current consumption, operating voltageTyp. 65 mA
Nominal operating voltage DC24 V
Power failure bridging10 ms
Isolation channel - internal busYes, for intermediate feed
Isolation channel - channelNo
Corrosion resistance class CRC(installed), 1 - Low corrosion stress
Storage temperature-20 to 70 °C
Degree of protectionIP65, IP67
Ambient temperature-5 to 50 °C
Product weight110 g
Max. address volume outputs32 Byte
Max. address volume inputs32 Byte
ProtocolIO-Link
Max. cable length20 m
Electrical connectionM12, 5 pin, A-coded, 2x socket
Note on materialsRoHS compliant
Material housingMakrolon, Reinforced PA
IO-Link, protocolMaster V 1.0
IO-Link, communication modeCOM1 (4.8 kB), COM2 (38.4 kB), COM3 (230.4 kB)
IO-Link, port typeAB
IO-Link, Number of ports2
IO-Link, Process data length OUTParameterisable 4/4 to 16/16 Bytes
IO-Link, Process data length INParameterisable 4/4 to 16/16 Bytes
IO-Link, Min. cycle timeMin. 1 ms per 1 Byte process data
IO-Link Master, output current1.6 A PL / Port, 1.6 A PS / Port
Weight0.14 kg
ManufacturerFesto
Hersteller-NrCPX-CTEL-2-M12-5POL-LK
EAN4052568255534
Zolltarifnummer85389099
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
MaterialPolyamide (PA)
Operating voltage24 V DC
Protection ratingIP65
Temperature (max.)50

Downloads

Accessories

Questions about this item

Any other question?