Images are examples, some edited with AI. The technical data are authoritative. AI notice
Electrical interface for CPX terminal, IO-Link protocol, 2 IO-Link ports, 24 V DC CPX-CTEL-2-M12-5POL-LK - Festo 2900543
The electrical interface CPX-CTEL-2-M12-5POL-LK is a genuine Festo part for the CPX terminal. The data sheet lists IO-Link protocol, 2 IO-Link ports and nominal operating voltage 24 V DC. It also offers power failure bridging 10 ms and IP65/IP67 protection.
Available
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The electrical interface CPX-CTEL-2-M12-5POL-LK is a genuine Festo part for the CPX terminal. The key selection criteria are IO-Link protocol and 2 IO-Link ports.
Advantages
- Fieldbus connection via IO-Link
- 2 IO-Link ports for sensors and actuators
- Nominal operating voltage 24 V DC
- Power failure bridging 10 ms
- IP65/IP67 protection for mounting directly on the machine
- Suitable for ambient temperatures of -5 to 50 °C
Application
CPX-CTEL-2-M12-5POL-LK is used when designing, extending and maintaining installations with the CPX terminal.
Technical data
| Type | CPX-CTEL-2-M12-5POL-LK |
|---|---|
| Festo part number | 2900543 |
| Series | CPX |
| Dimensions (W x L x H) | 50 mm x 107 mm x 55 mm, (Incl. linking block) |
| Diagnosis | Unterspannung, Kommunikationsfehler, Kurzschluss Module, Modulorientierte Diagnose |
| Parameterisation | Diagnostic behaviour, fail-safe per channel, forcing per channel, idle mode per channel, module parameters |
| Operator controls | DIL switch |
| LED display | PL: Load supply, PS: Electronic supply, sensor supply, Collective diagnosis, X1: System status IO link port 1, X1: System status IO link port 2 |
| Operational voltage range DC | 18 to 30 V |
| Internal current consumption, operating voltage | Typ. 65 mA |
| Nominal operating voltage DC | 24 V |
| Power failure bridging | 10 ms |
| Isolation channel - internal bus | Yes, for intermediate feed |
| Isolation channel - channel | No |
| Corrosion resistance class CRC | (installed), 1 - Low corrosion stress |
| Storage temperature | -20 to 70 °C |
| Degree of protection | IP65, IP67 |
| Ambient temperature | -5 to 50 °C |
| Product weight | 110 g |
| Max. address volume outputs | 32 Byte |
| Max. address volume inputs | 32 Byte |
| Protocol | IO-Link |
| Max. cable length | 20 m |
| Electrical connection | M12, 5 pin, A-coded, 2x socket |
| Note on materials | RoHS compliant |
| Material housing | Makrolon, Reinforced PA |
| IO-Link, protocol | Master V 1.0 |
| IO-Link, communication mode | COM1 (4.8 kB), COM2 (38.4 kB), COM3 (230.4 kB) |
| IO-Link, port type | AB |
| IO-Link, Number of ports | 2 |
| IO-Link, Process data length OUT | Parameterisable 4/4 to 16/16 Bytes |
| IO-Link, Process data length IN | Parameterisable 4/4 to 16/16 Bytes |
| IO-Link, Min. cycle time | Min. 1 ms per 1 Byte process data |
| IO-Link Master, output current | 1.6 A PL / Port, 1.6 A PS / Port |
| Weight | 0.14 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPX-CTEL-2-M12-5POL-LK |
| EAN | 4052568255534 |
| Zolltarifnummer | 85389099 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Polyamide (PA) |
| Operating voltage | 24 V DC |
| Protection rating | IP65 |
| Temperature (max.) | 50 |
Downloads
Accessories
Control block for CPX terminal, CODESYS Level 2, EasyIP protocol, 24 V DC, IP65 CPX-CEC-S1-V3 - Festo 3472425
Item FES-3472425Control block for CPX terminal, CODESYS Level 2, EasyIP protocol, 24 V DC, IP65 CPX-CEC-C1-V3 - Festo 3473128
Item FES-3473128Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.