Solenoid valve 3/2-way normally closed monostable QS-8 CPE18-M3H-3GLS-QS-8 - Festo 163797
Slim 3/2-way solenoid valve delivering 850 l/min at just 18 mm width, normally closed. QS-8 supply port, operating pressure -0.9 to 10 bar with external pilot air. 230 V AC coil (3 VA pull-in, 2.4 VA holding), IP65. Festo type CPE18-M3H-3GLS-QS-8. c UL us - Recognized (OL) certified.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
18 mm width and 850 l/min flow: the CPE18-M3H-3GLS-QS-8 from the Festo CPE18 series works as a 3/2-way valve, normally closed. In the normal position the path from 1 to 2 is closed and only the signal releases the air, suitable for single-acting cylinders, blow-off air or vacuum generators.
Benefits
- 8 mm nominal size and 850 l/min within 18 mm width, suited to densely packed valve rows.
- Operating pressure -0.9 to 10 bar, including vacuum, the pilot stage is supplied externally at 2.5 to 10 bar.
- Quick cycling: 28 ms switch-on and 18 ms switch-off time.
- The 230 V AC coil of the CPE18-M3H-3GLS-QS-8 draws 3 VA pull-in, 2.4 VA holding, 100 % duty cycle, connection type C plug pattern to EN 175301-803.
- Approved to c UL us - Recognized (OL), degree of protection IP65 to IEC 60529.
- Pneumatic ports 1 and 2 in QS-8, 3 in G1/4, pilot air M5.
Application and mounting
Lines are connected to the QS-8 push-in connectors and the CPE18-M3H-3GLS-QS-8 is bolted through its through-holes, the mounting position can be chosen freely. The CPE18-M3H-3GLS-QS-8 runs on compressed air to ISO 8573-1:2010 [7:4:4], lubricated operation is possible but must then be maintained.
Technical data
| Type | CPE18-M3H-3GLS-QS-8 |
|---|---|
| Festo part number | 163797 |
| Valve function | 3/2-way, normally closed, monostable |
| Type of actuation | electrical |
| Width | 18 mm |
| Standard nominal flow rate | 850 l/min |
| Operating pressure | -0.9 to 10 bar |
| Design | piston spool |
| Type of reset | pneumatic spring |
| Certification | c UL us - Recognized (OL) |
| Marine classification | see certificate |
| Degree of protection | IP65 with plug socket to IEC 60529 |
| Nominal size | 8 mm |
| Sealing principle | soft |
| Mounting position | any |
| Manual override | non-detenting, detenting with accessory |
| Type of piloting | piloted |
| Pilot air supply | external |
| Flow direction | non-reversible |
| Valve position identification | label holder |
| Overlap | positive overlap |
| Switching time off | 18 ms |
| Switching time on | 28 ms |
| Duty cycle | 100 % |
| Maximum positive test pulse with 0 signal | 3300 µs |
| Maximum negative test pulse with 1 signal | 3100 µs |
| Coil characteristics | 230 V AC, 50/60 Hz, pull-in power 3 VA, holding power 2.4 VA |
| Permissible voltage fluctuations | -15 % / +10 % |
| Operating medium | compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | lubricated operation possible (then required for all further operation) |
| Vibration resistance | transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - moderate corrosion stress |
| Medium temperature | -5 to 50 °C |
| Ambient temperature | -5 to 50 °C |
| Electrical connection | plug pattern type C to EN 175301-803 |
| Type of mounting | with through-hole |
| Pilot exhaust air port 82 | M5 |
| Pilot air port 12 | M5 |
| Pneumatic connection, port 1 | QS-8 |
| Pneumatic connection, port 2 | QS-8 |
| Pneumatic connection, port 3 | G1/4 |
| Note on materials | RoHS compliant |
| Seal material | NBR |
| Housing material | die-cast aluminium |
| Pilot pressure | 2.5 to 10 bar |
| Pilot medium | compressed air to ISO 8573-1:2010 [7:4:4] |
| Weight | 0.28 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPE18-M3H-3GLS-QS-8 |
| EAN | 4052568135539 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Aluminium |
| For hose OD [mm] | 8 |
| Nominal size DN [mm] | 8 |
| Medium | Compressed air |
| Function | 3/2 closed monostable |
| Flow rate [l/min] | 850 |
| Actuation type | Electrical |
| Norm | DIN EN 175301-803 |
| Operating conditions | EN 60068-2-27, EN 60068-2-6, ISO 8573-1 |
| Operating voltage | 230 V AC |
| Series | CPE18 |
| Betriebsdruck max [bar] | 10 |
| Pneumatic connection | QS-8 |
| Protection rating | IP65 |
| Temperature (max.) | 50 |
Downloads
Accessories
Solenoid valve 3/2-way normally closed monostable G1/4 CPE18-M3H-3GLS-1/4 - Festo 163789
Item FES-163789Solenoid valve 3/2-way normally closed monostable QS-10 CPE18-M3H-3GL-QS-10 - Festo 163801
Item FES-163801Solenoid valve 3/2-way normally closed monostable QS-8 CPE18-M3H-3GL-QS-8 - Festo 163793
Item FES-163793Solenoid valve 3/2-way normally closed monostable G1/4 CPE18-M3H-3GL-1/4 - Festo 163785
Item FES-163785Solenoid valve 3/2-way normally open monostable QS-8 CPE18-M3H-3OLS-QS-8 - Festo 163796
Item FES-163796Alternatives
Solenoid valve 3/2-way normally open monostable QS-10 CPE18-M1H-3OL-QS-10 - Festo 163156
Item FES-163156Solenoid valve 5/3-way mid-position closed QS-10 CPE18-M1H-5/3G-QS-10 - Festo 170259
Item FES-170259Solenoid valve 5/3-way mid-position exhausted G1/4 CPE18-M1H-5/3E-1/4 - Festo 170249
Item FES-170249Solenoid valve 3/2-way normally closed monostable G1/4 CPE18-M1H-3GL-1/4 - Festo 163141
Item FES-163141Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.