Solenoid valve 5/2-way monostable QS-8 CPE18-M1H-5LS-QS-8 - Festo 163154
Slim 5/2-way solenoid valve delivering 850 l/min at just 18 mm width, monostable. External pilot air (2.5 to 10 bar) allows -0.9 to 10 bar operating pressure, including vacuum. 24 V DC coil (1.5 W), IP65. Festo type CPE18-M1H-5LS-QS-8. c UL us - Recognized (OL) certified.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
18 mm width and 850 l/min flow: the CPE18-M1H-5LS-QS-8 from the Festo CPE18 series works as a 5/2-way valve, monostable. For double-acting cylinders that must return to a defined home position on signal loss, the monostable version with pneumatic spring is the right choice.
Benefits
- 850 l/min standard nominal flow at just 18 mm width and 8 mm nominal size.
- The CPE18-M1H-5LS-QS-8 works with external pilot air (2.5 to 10 bar) across an operating range of -0.9 to 10 bar, including vacuum.
- Switching time 26 ms on and 20 ms off.
- The 24 V DC coil of the CPE18-M1H-5LS-QS-8 draws 1.5 W, 100 % duty cycle, connection type C plug pattern to EN 175301-803.
- IP65 degree of protection with plug socket to IEC 60529, c UL us - Recognized (OL) certification.
- Port assignment 1, 2 and 4 in QS-8, 3 and 5 in G1/4, pilot ports M5.
Application and mounting
The CPE18-M1H-5LS-QS-8 is connected via the QS-8 push-in connectors and fastened through its through-holes in any mounting position. Reversible flow direction: supply and exhaust can also be connected the other way round on the CPE18-M1H-5LS-QS-8.
Technical data
| Type | CPE18-M1H-5LS-QS-8 |
|---|---|
| Festo part number | 163154 |
| Valve function | 5/2-way, monostable |
| Type of actuation | electrical |
| Width | 18 mm |
| Standard nominal flow rate | 850 l/min |
| Operating pressure | -0.9 to 10 bar |
| Design | piston spool |
| Type of reset | pneumatic spring |
| Certification | c UL us - Recognized (OL) |
| Marine classification | see certificate |
| Degree of protection | IP65 with plug socket to IEC 60529 |
| Nominal size | 8 mm |
| Sealing principle | soft |
| Mounting position | any |
| Manual override | non-detenting, detenting with accessory |
| Type of piloting | piloted |
| Pilot air supply | external |
| Flow direction | reversible |
| Valve position identification | label holder |
| Overlap | positive overlap |
| Switching time off | 20 ms |
| Switching time on | 26 ms |
| Duty cycle | 100 % |
| Maximum positive test pulse with 0 signal | 3300 µs |
| Maximum negative test pulse with 1 signal | 3100 µs |
| Coil characteristics | 24 V DC, 1.5 W |
| Permissible voltage fluctuations | -15 % / +10 % |
| Operating medium | compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | lubricated operation possible (then required for all further operation) |
| Vibration resistance | transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - moderate corrosion stress |
| Medium temperature | -5 to 50 °C |
| Ambient temperature | -5 to 50 °C |
| Electrical connection | plug pattern type C to EN 175301-803 |
| Type of mounting | with through-hole |
| Pilot exhaust air port 82 | M5 |
| Pilot air port 12 | M5 |
| Pneumatic connection, port 1 | QS-8 |
| Pneumatic connection, port 2 | QS-8 |
| Pneumatic connection, port 3 | G1/4 |
| Note on materials | RoHS compliant |
| Seal material | NBR |
| Housing material | die-cast aluminium |
| Exhaust function | can be throttled |
| Pilot exhaust air port 84 | M5 |
| Pilot air port 14 | M5 |
| Pneumatic connection, port 4 | QS-8 |
| Pneumatic connection, port 5 | G1/4 |
| Pilot pressure | 2.5 to 10 bar |
| Pilot medium | compressed air to ISO 8573-1:2010 [7:4:4] |
| Weight | 0.27 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPE18-M1H-5LS-QS-8 |
| EAN | 4052568133160 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Aluminium |
| For hose OD [mm] | 8 |
| Nominal size DN [mm] | 8 |
| Medium | Compressed air |
| Function | 5/2 monostable |
| Flow rate [l/min] | 850 |
| Actuation type | Electrical |
| Norm | DIN EN 175301-803 |
| Operating conditions | EN 60068-2-27, EN 60068-2-6, ISO 8573-1 |
| Operating voltage | 24 V DC |
| Series | CPE18 |
| Betriebsdruck max [bar] | 10 |
| Pneumatic connection | QS-8 |
| Protection rating | IP65 |
| Temperature (max.) | 50 |
Downloads
Accessories
Solenoid valve 5/2-way monostable G1/4 CPE18-M1H-5LS-1/4 - Festo 163146
Item FES-163146Solenoid valve 5/2-way monostable QS-10 CPE18-M1H-5L-QS-10 - Festo 163158
Item FES-163158Solenoid valve 5/2-way monostable QS-8 CPE18-M1H-5L-QS-8 - Festo 163150
Item FES-163150Solenoid valve 5/2-way monostable G1/4 CPE18-M1H-5L-1/4 - Festo 163142
Item FES-163142Solenoid valve 5/2-way bistable QS-8 CPE18-M1H-5JS-QS-8 - Festo 163155
Item FES-163155Alternatives
Solenoid valve 3/2-way normally open monostable QS-10 CPE18-M1H-3OL-QS-10 - Festo 163156
Item FES-163156Solenoid valve 5/3-way mid-position closed QS-10 CPE18-M1H-5/3G-QS-10 - Festo 170259
Item FES-170259Solenoid valve 5/3-way mid-position exhausted G1/4 CPE18-M1H-5/3E-1/4 - Festo 170249
Item FES-170249Solenoid valve 3/2-way normally closed monostable G1/4 CPE18-M1H-3GL-1/4 - Festo 163141
Item FES-163141Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.