Solenoid valve 3/2-way normally closed monostable QS-6 CPE10-M1BH-3GLS-QS-6 - Festo 196850
Slim 3/2-way solenoid valve delivering 300 l/min at just 10 mm width, normally closed. Operating pressure -0.9 to 10 bar with external pilot air at 2.5 to 8 bar, switching time 14 ms on and 14 ms off. 24 V DC coil (1.28 W), IP65. Festo type CPE10-M1BH-3GLS-QS-6. c UL us - Recognized (OL) certified.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
With 300 l/min standard nominal flow at 10 mm width, the CPE10-M1BH-3GLS-QS-6 solenoid valve puts a lot of air capacity into a narrow valve row. The valve function is 3/2-way, normally closed. The normally closed function ensures that no compressed air flows to the consumer in the event of a power failure.
Benefits
- 300 l/min standard nominal flow at just 10 mm width and 4 mm nominal size.
- The CPE10-M1BH-3GLS-QS-6 works with external pilot air (2.5 to 8 bar) across an operating range of -0.9 to 10 bar, including vacuum.
- Quick cycling: 14 ms switch-on and 14 ms switch-off time.
- 24 V DC coil with 1.28 W, 100 % with holding current reduction duty cycle, 2-pin plug connection, IP65 with plug socket.
- Port assignment 1 and 2 in QS-6, 3 in M7, pilot ports M3.
- Tested to EN 60068-2-6 and EN 60068-2-27, CRC 2 and usable at -5 to 50 °C ambient temperature.
Application and mounting
The CPE10-M1BH-3GLS-QS-6 is connected via the QS-6 push-in connectors and fastened through its through-holes in any mounting position. The CPE10-M1BH-3GLS-QS-6 runs on compressed air to ISO 8573-1:2010 [7:4:4], lubricated operation is possible but must then be maintained.
Technical data
| Type | CPE10-M1BH-3GLS-QS-6 |
|---|---|
| Festo part number | 196850 |
| Valve function | 3/2-way, normally closed, monostable |
| Type of actuation | electrical |
| Width | 10 mm |
| Standard nominal flow rate | 300 l/min |
| Operating pressure | -0.9 to 10 bar |
| Design | piston spool |
| Type of reset | pneumatic spring |
| Certification | c UL us - Recognized (OL) |
| Marine classification | see certificate |
| Degree of protection | IP65 with plug socket to IEC 60529 |
| Nominal size | 4 mm |
| Sealing principle | soft |
| Mounting position | any |
| Manual override | non-detenting, detenting with accessory |
| Type of piloting | piloted |
| Pilot air supply | external |
| Flow direction | non-reversible |
| Valve position identification | label holder |
| Overlap | positive overlap |
| Switching time off | 14 ms |
| Switching time on | 14 ms |
| Duty cycle | 100 % with holding current reduction |
| Maximum positive test pulse with 0 signal | 1200 µs |
| Maximum negative test pulse with 1 signal | 900 µs |
| Coil characteristics | 24 V DC, 1.28 W |
| Permissible voltage fluctuations | -15 % / +10 % |
| Operating medium | compressed air to ISO 8573-1:2010 [7:4:4] |
| Note on operating and pilot medium | lubricated operation possible (then required for all further operation) |
| Vibration resistance | transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistance class CRC | 2 - moderate corrosion stress |
| Medium temperature | -5 to 50 °C |
| Ambient temperature | -5 to 50 °C |
| Electrical connection | 2-pin |
| Type of mounting | with through-hole |
| Pilot exhaust air port 82 | M3 |
| Pilot air port 12 | M3 |
| Pneumatic connection, port 1 | QS-6 |
| Pneumatic connection, port 2 | QS-6 |
| Pneumatic connection, port 3 | M7 |
| Note on materials | RoHS compliant |
| Seal material | NBR |
| Housing material | die-cast aluminium |
| Pilot pressure | 2.5 to 8 bar |
| Pilot medium | compressed air to ISO 8573-1:2010 [7:4:4] |
| Weight | 0.06 kg |
| Manufacturer | Festo |
| Hersteller-Nr | CPE10-M1BH-3GLS-QS-6 |
| EAN | 4052568159603 |
| Zolltarifnummer | 84812090 |
| GPSR Herstellerdaten | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Material | Aluminium |
| For hose OD [mm] | 6 |
| Nominal size DN [mm] | 4 |
| Medium | Compressed air |
| Function | 3/2 closed monostable |
| Flow rate [l/min] | 300 |
| Actuation type | Electrical |
| Operating conditions | EN 60068-2-27, EN 60068-2-6, ISO 8573-1 |
| Operating voltage | 24 V DC |
| Series | CPE10 |
| Betriebsdruck max [bar] | 10 |
| Pneumatic connection | QS-6 |
| Protection rating | IP65 |
| Temperature (max.) | 50 |
Downloads
Accessories
Solenoid valve 3/2-way normally closed monostable M5 CPE10-M1BH-3GLS-M5 - Festo 196848
Item FES-196848Solenoid valve 3/2-way normally closed monostable M7 CPE10-M1BH-3GLS-M7 - Festo 196916
Item FES-196916Solenoid valve 3/2-way normally closed monostable QS-6 CPE10-M1BH-3GL-QS-6 - Festo 196847
Item FES-196847Solenoid valve 3/2-way normally closed monostable QS-4 CPE10-M1BH-3GL-QS-4 - Festo 196846
Item FES-196846Solenoid valve 3/2-way normally closed monostable M5 CPE10-M1BH-3GL-M5 - Festo 196845
Item FES-196845Alternatives
Solenoid valve 5/2-way bistable QS-6 CPE10-M1BH-5J-QS-6 - Festo 196877
Item FES-196877Solenoid valve 3/2-way normally closed monostable M7 CPE10-M1BH-3GL-M7 - Festo 196915
Item FES-196915Questions about this item
Any other question?
Send us the item number and your question. We clarify technical details directly with the manufacturer and usually reply on the next working day.