Images are examples, some edited with AI. The technical data are authoritative. AI notice

Safety module STO, SLS, SBC, SOS, SS1, SS2, SSR, SSM, up to category 4, PL e CAMC-G-S3 - Festo 1501331

Festo ✓ Original product Brand new

The Festo safety module CAMC-G-S3 offers safety functions STO, SLS, SBC, SOS, SS1, SS2, SSR, SSM, usable up to category 4, PL e, 10 digital logic inputs. As a plug-in module, it plugs directly into the CMMP-AS...-M3 motor controller. Further data: 24 V DC. Product weight 220 g, RoHS compliant.

Net
€573.41
excl. VAT
Item FES-1501331
Manufacturer no. CAMC-G-S3

Available

Question about this item
  • Specialist dealer since 2009
  • Invoice payment for regular customers
  • Worldwide shipping
  • Technical questions clarified with the manufacturer

Description

The Festo safety module CAMC-G-S3 offers safety functions STO, SLS, SBC, SOS, SS1, SS2, SSR, SSM, usable up to category 4, PL e, 10 digital logic inputs.

Benefits

  • Safety function: Safe torque off (STO), Safely limited speed (SLS), Safe brake control (SBC), Safe operating stop (SOS), Safe stop 1 (SS1), Safe stop 2 (SS2), Safe speed range (SSR), Safe speed monitor (SSM)
  • Certified for safety functions to ISO 13849 (PL): Product can be used in SRP/CS up to category 4, PL e
  • Number of digital logic inputs: 10
  • Nominal operating voltage DC: 24 V

Applications

As a plug-in module, it plugs directly into the CMMP-AS...-M3 motor controller. Product weight 220 g, RoHS compliant.

Technical data

Note on materialsContains paint-wetting impairment substances (LABS), RoHS compliant
Nominal voltage for logic power supply DC24 V
Nominal operating voltage DC24 V
Nominal current logic supply0.15 A
Permissible range for logic voltage± 20 %
Current consumption of logic power supply without clamping brake0.2 A
Short circuit current ratingYes, exception: contact C1/C2
Current rating at 40° C0.2 A
Fuse protection (short circuit)No
Digital output designFloating signal contact, 3 safe 2-channel semiconductor outputs
Number of digital logic inputs10
Digital outputs, switching logicSemiconductor outputs: parameterisable PNP (positive switching), 2-channel equivalent / antivalent
Dimensions (W x L x H)112.2 mm x 99.1 mm x 28.7 mm
LED display, product-specificError (red), Normal operation (green), Safe state (yellow)
Safety functionSafe torque off (STO), Safely limited speed (SLS), Safe brake control (SBC), Safe operating stop (SOS), Safe stop 1 (SS1), Safe stop 2 (SS2), Safe speed range (SSR), Safe speed monitor (SSM)
PFH (probability of failure per hour)9.5 × 10⁻⁹ 1/h
Proof test interval20 years
Hardware fault tolerance1
SFF Safe Failure Fraction99.5 %
Certified for safety function to ISO 13849 and IEC 61508 (SIL)Product can be used in SRP/CS up to SIL 3 high demand
Safety Integrity Level (SIL)Safe torque off (STO) / SIL 3, Safe brake control (SBC) / SIL 3, Safely limited speed (SLS) / SIL 3, Safe operating stop (SOS) / SIL 3, Safe stop 1 (SS1) / SIL 3, Safe stop 2 (SS2) / SIL 3, Safe speed monitor (SSM) / SIL 3, Safe speed range (SSR) / SIL 3
Performance Level (PL)Safe Torque Off (STO)/category 4, performance level e, Safe brake control (SBC) / category 4, performance level e, Safely limited speed (SLS) / category 3, performance level e, Safe operating stop (SOS) / category 3, performance level e, Safe stop 1 (SS1) / category 3, performance level e, Safe stop 2 (SS2) / category 3, performance level e, Safe speed monitor (SSM) / category 3, performance level e, Safe speed range (SSR) / category 3, performance level e
Diagnostic coverage97.5 %
Certified for safety functions to ISO 13849 (PL)Product can be used in SRP/CS up to category 4, PL e
ApprovalTÜV
CE mark (see declaration of conformity)To EU EMC Directive, To EU Machinery Directive
Certificate issuing authority01/205/5165.02/19, TÜV Rheinland
Storage temperature-25 to 55 °C
Relative air humidity5 - 90%, non-condensing
Degree of protectionIP20, In mounted state
Ambient temperature0 to 40 °C
Product weight220 g
Type of mountingPlug-in module for CMMP-AS...-M3
Mounting positionAny
Wire endsWire ferrule
Connection cross section0.25 to 0.5 mm²
Electrical connectionScrew terminal, straight plug
DisplayGreen/yellow/red LED
Operator controlsDIP switch
Specification logic inputIEC 61131-2, type 3
Features of logic input4 safe 2-channel inputs (equivalent or antivalent switching, test pulses and function configurable), 6 safe 1-channel inputs (test pulses configurable)
Working range of logic input13 to 28.8 V
Maximum nominal input current0.015 A
Debounce time inputs0.3 ms
Current rating per output50 mA
Maximum current digital logic outputs50 mA
Output protectionShort-circuit and cross-circuit monitoring
Minimum cycle time2 ms
Weight0.24 kg
ManufacturerFesto
Hersteller-NrCAMC-G-S3
EAN4052568237950
Zolltarifnummer85389099
GPSR HerstellerdatenFesto Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com
ArtikelzustandNew
Artikel-AuthentizitätOriginal product
NormDIN EN 61131-2
CertificationDIN EN ISO 13849, IEC 61508
Operating voltage24 V DC
SeriesCAMC
Protection ratingIP20
Temperaturbereich0-40 °C
Temperature (max.)40

Downloads

Accessories

Questions about this item

Any other question?