3/2-way solenoid valve, Banjo connection, NC - Riegler K920
-
This Item:
€63.48
-
2/2-solenoid valve,NC - Riegler K902
As low as €30.04Show details
-
2/2 solenoid valve, NC, G 2, PN 0.5-10, NBR, pilot-op., 24V AC - Riegler 129551
€337.35
3/2-way solenoid valve, Banjo connection, NC. This range covers 2 variants from 63.48 EUR. Select the version you need above.
Available variants
| Voltage | 230 V AC, 24 V DC |
|---|
Shared technical data
| A | 79,0 mm |
|---|---|
| Port 1 | Steckanschluss für Schlauch-Außen-Ø 4 mm |
| Port 2 | Gewinde G 1/8 |
| B | 90,0 mm |
| Max. operating pressure | 10 bar |
| Max. operating temperature | 60 °C |
| Min. operating temperature | 0 °C |
| C | 49,0 mm |
| D | 58,0 mm |
| Sealant | NBR |
| Vent port | M5 |
| Function | stromlos geschlossen (NC) |
| Housing | Polyamid (glasfaserverstärkt) |
| Thread | G 1/8 AG |
| Max. medium temperature | 60 °C |
| Min. medium temperature | -10 °C |
| Max. ambient temperature | 60 °C |
| Min. ambient temperature | -10 °C |
| Customs tariff number | 84812090 |
About Solenoid valves
Solenoid valves switch a media flow electrically, with no manual intervention at the line. The range covers nominal sizes from DN 1 to DN 66 and operating pressures up to 50 bar, with ports from G 1/8 to G 2. Some versions work from -1 bar upwards, which makes them suitable for vacuum duty.
What matters when choosing
- Function: normally closed (NC), normally open (NO) or any flow direction (BEL). What matters is the state the plant should assume when power is lost.
- Voltage: 12 V DC, 24 V DC, 24 V AC, 110 V AC and 230 V AC, plus 24 V AC/DC and 230 V AC/DC versions. Follow whatever the existing control system supplies.
- Sealing material NBR, FKM, FPM, EPDM, PTFE or FFKM: match the elastomer to the medium and to the media temperature, which runs between -30 and 160 °C depending on version.
- Body material: brass, aluminium, polyamide, glass-fibre reinforced polyamide, polypropylene or stainless steel 1.4301, 1.4401 and 1.4581. Stainless steel is the choice for corrosive media and demanding wash-down regimes.
- Nominal size DN 1 to 66 mm and operating pressure: upper limits run from 1 to 50 bar, and nominal size sets the achievable flow.
Typical applications
- Shutting off and releasing compressed air in machines and plant
- Cleaning fabric filters in dust collection systems using pulse diaphragm valves
- Switching duties in cooling and heating water circuits
- Dosing and filling stations handling thin, neutral media
- Vacuum applications with operating pressures from -1 bar
Threads are made to DIN EN ISO 228-1 or ISO 7-1. Protection class IP 65 or IP 67 is reached with the connector socket correctly fitted.
| Manufacturer | Riegler |
|---|---|
| GPSR Herstellerdaten | Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Norm | DIN EN ISO 228-1 |