Images are examples, some edited with AI. The technical data are authoritative. AI notice
2/2-way solenoid valve NC, force pilot operated, brass, G 2, DN 50, 0 to 12 bar, FPM, 230 V AC, type MVA.2.MS.230.F.RZ.50 - Riegler 129406
This normally closed 2/2-way solenoid valve shuts off when power fails and only opens when the 230 V AC coil is energised. G 2 port, DN 50, FPM seals and brass housing. Medium temperature -10 to 100 °C, operating pressure 0 to 12 bar.
- Specialist dealer since 2009
- Invoice payment for regular customers
- Worldwide shipping
- Technical questions clarified with the manufacturer
Description
The 2/2-way solenoid valve MVA.2.MS.230.F.RZ.50 switches fluids electrically, with no manual intervention at the line. It operates in the range 0 to 12 bar at nominal size DN 50 and is force pilot operated.
Benefits
- Fail-safe NC position: without 230 V AC on the coil the flow path stays closed.
- Force pilot operated from 0 bar: switches without minimum pressure up to 12 bar at DN 50.
- Internal parts in brass and stainless steel, housing in brass and seat in brass and stainless steel, DN 50.
- FPM seal material for media from -10 to 100 °C at 0 to 12 bar.
- Electrics: 230 V AC, connector socket, industrial standard type A, EN 175301-803-A, degree of protection IP 65 (with connector socket fitted).
Applications
It is used in plant engineering, process technology and filling systems. The ambient temperature may be -10 to 50 °C, the medium -10 to 100 °C. Choose the NC version MVA.2.MS.230.F.RZ.50 if the system must shut off safely when power fails.
Technical data
| Type no. | MVA.2.MS.230.F.RZ.50 |
|---|---|
| Design type | 2/2-way solenoid valve |
| Operation | force pilot operated |
| Function | normally closed (NC) |
| Port thread | G 2 |
| Thread standard | DIN EN ISO 228-1 |
| Nominal size DN | 50 mm |
| Operating pressure | 0 to 12 bar |
| Medium temperature | -10 to 100 °C |
| Ambient temperature | -10 to 50 °C |
| Degree of protection | IP 65 (with connector socket fitted) |
| Electrical connection | connector socket, industrial standard type A, EN 175301-803-A |
| Housing | brass |
| Valve seat | brass and stainless steel |
| Internal parts | brass and stainless steel |
| Seal material | FPM |
| Voltage | 230 V AC |
| Dimension A | 160.0 mm |
| Dimension B | 225.0 mm |
| Dimension C | 112.0 mm |
| Weight | 6.15 kg |
| Manufacturer | Riegler |
| Hersteller-Nr | MVA.2.MS.230.F.RZ.50 |
| EAN | 4047322730822 |
| Zolltarifnummer | 84818079 |
| GPSR Herstellerdaten | Riegler & Co. KG, Schützenstraße 27, DE-72574 Bad Urach, www.riegler.de |
| Artikelzustand | New |
| Artikel-Authentizität | Original product |
| Country of Manufacture | Germany |
| Ausführung | zwangsgesteuert |
| Material | Brass |
| Thread | G 2 |
| Nominal size DN [mm] | 50 |
| Housing material | Brass |
| Actuation type | Electrical |
| Medientemperatur [°C] | -10 bis 100 |
| Norm | DIN EN 175301-803, DIN EN ISO 228-1 |
| Operating voltage | 230 V AC |
| Betriebsdruck max [bar] | 12 |
| Pneumatic connection | G2 |
| Protection rating | IP65 |
| Temperaturbereich | -10-100 °C |
| Temperature (max.) | 100 |