CPX-4AE-4AA-H
Input module
Frequently Bought Together
-
This Item:
€529.81Excl. 19% VAT , excl. Shipping Cost
-
Festo 8022172. Interlinking block CPX-GE-EV-S-7/8-5POL-VL
€87.34Excl. 19% VAT , excl. Shipping Cost
-
Festo 542124. AS-i module ASI-8DI-M8-3POL
€290.99Excl. 19% VAT , excl. Shipping Cost
Total price
Protocol | HART |
Dimensions (W x L x H) | (incl. interlinking block and connection technology) 50 x 107 x 70 mm |
Grid dimension | 50 mm |
Type of mounting | On interlinking block |
Product weight | 77.4 g |
Ambient temperature | -5 °C ... 50 °C |
Storage temperature | -20 °C ... 70 °C |
Relative air humidity | 95 % Non-condensing |
Degree of protection | Dependent on the manifold block |
Corrosion resistance class CRC | 1 - Low corrosion stress (when installed) |
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
Max. cable length | 500 m |
LABS (PWIS) conformity | VDMA24364-B2-L |
CE mark (see declaration of conformity) | To EU EMC Directive |
Note on materials | RoHS-compliant |
Material housing | PA-reinforced PC |
LED display | 1 Group diagnostics 4 channel diagnostics 4 Channel status |
Diagnosis | Wire break per channel Limit value violation per channel Short circuit/overload per channel Parameterisation error Overflow/underflow Limit value violation as per NE43 per channel |
Operator controls | DIL switch |
Parameterisation | Data format Fail-safe per channel Forcing per channel Limit monitoring per channel Idle mode per channel Measured value smoothing Signal range per channel Overflow/underflow monitoring Monitoring according to NE43 inputs Wire break monitoring per channel Number of HART repetitions Wire break per channel Limit value violation as per NE43 per channel Limit value violation per channel HART variables Hysteresis for critical limits Short circuit/overload per channel Parameterisation error Overflow/underflow Behaviour after short circuit/overload |
Max. load | 750 Ohm |
Operational voltage range DC | 18 V ... 30 V |
Nominal operating voltage DC | 24 V |
Intern power consumption nominal operating voltage | Typ. 170 mA |
Power failure bridging | 10 ms |
Reverse polarity protection | For all electrical connections |
Min. available sensor voltage | 20.7 V at 20 mA |
Max. input resistance | 300 Ohm |
Number of selectable analogue inputs/outputs | 4 |
Data format | 15 bits + prefix Scalable to 15 bits |
analog input | 0 - 20 mA 4 - 20 mA 4 - 20 mA with HART |
Repetition accuracy | 0.05% at 25ºC |
Basic error limit at 25 °C | ±0.1% |
Operating error limit related to the ambient temperature range | ±0.3% |
Sensor type | 0 - 20 mA 4 - 20 mA 4 - 20 mA with HART |
Max. open circuit voltage | 28.8 V |
Isolation channel - channel | no |
Isolation channel - internal bus | yes |
Max. short circuit current | 22 mA |
Fuse protection (short circuit) | Internal electronic fuse per channel |
Manufacturer Nr. | CPX-4AE-4AA-H |
---|---|
Manufacturer | Festo |
EAN | 4052568295622 |
Weight | 0.105000 |
HS-Code | 85389099 |