€1,247.02
Excl. 19% VAT ,
excl. Shipping Cost
Article
FES-4252742
Manufacturer Nr.
CPX-E-CEC-C1-EP
Controller
Frequently Bought Together
-
This Item:
€1,247.02Excl. 19% VAT , excl. Shipping Cost
-
Festo 574418. controller CECC-LK
€99,999.00Excl. 19% VAT , excl. Shipping Cost
-
Festo 4025. Pulse oscillator VLG-4-1/8
€1,049.42Excl. 19% VAT , excl. Shipping Cost
Total price
| Dimensions (W x L x H) | 75.9 x 124.3 x 82.5 mm |
| Grid dimension | 18.9 mm |
| Type of mounting | With H-rail |
| Max. number of modules | 10 |
| Product weight | 288 g |
| Mounting position | Vertical Horizontal |
| Ambient temperature | -5 °C ... 50 °C |
| Note on ambient temperature | -5 - 60°C for vertical installation |
| Storage temperature | -20 °C ... 70 °C |
| Relative air humidity | 95 % Non-condensing |
| Degree of protection | IP20 |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Protection against direct and indirect contact | PELV |
| LABS (PWIS) conformity | VDMA24364 zone III |
| CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive |
| CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions |
| KC mark | KC-EMV |
| Approval | RCM trademark c UL us listed (OL) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS-compliant |
| Material housing | PA |
| Material screws | Galvanised steel |
| Diagnostics via LED | Module status Network status Network status, engineering port 1 Network status, engineering port 2 EtherCAT® network status Network status, port 1 Network status, port 2 Run Power supply, electronics/sensors Load power supply System fault |
| Operator controls | DIL switch for RUN/STOP Rotary switch for address setting Optional: CDSB operator unit |
| IP address setting | DHCP Via CODESYS Optional: via operator unit CDSB |
| Fieldbus interface | Ethernet |
| Field bus, protocol | ACD (Address Conflict Detection) DLR (Device Level Ring) EtherNet/IP EtherNet/IP QoS EtherNet/IP Quickconnect SNMP |
| Fieldbus interface, function | Bus connection incoming/outgoing |
| Field bus, connection type | 2x socket |
| Field bus, connection system | RJ45 |
| Fieldbus interface, connection pattern | 00995789 |
| Field bus, connection pattern | 8 |
| Field bus interface, electrical isolation | yes |
| Field bus interface, transmission rate | 100 Mbit/s |
| Fieldbus interface 2, type | Ethernet |
| Fieldbus interface 2, protocol | CoE EoE EtherCAT® FoE |
| Fieldbus interface 2, function | Outgoing bus connection |
| Fieldbus interface 2, connection type | Socket |
| Fieldbus interface 2, connection technology | RJ45 |
| Fieldbus interface 2, connection pattern | 00995789 |
| Fieldbus interface 2, number of pins/wires | 8 |
| Fieldbus interface 2, galvanic isolation | yes |
| Fieldbus interface 2, transmission rate | 100 Mbit/s |
| Ethernet interface, connection type | 2x socket |
| Ethernet interface, protocol | EasyIP Modbus® TCP OPC UA TCP/IP |
| Ethernet interface, function | Diagnostics Switch |
| Ethernet interface, connection system | RJ45 |
| Ethernet interface, connection pattern | 00995789 |
| Ethernet interface, number of pins/wires | 8 |
| Ethernet interface, transmission rate | 10 Mbit/s 100 Mbit/s |
| Max. address volume, inputs | 64 Byte |
| Fieldbus interface, max. address volume for inputs | 512 Byte |
| Max. address volume, outputs | 64 Byte |
| Fieldbus interface, max. address volume for outputs | 512 Byte |
| System parameters | Diagnostic memory Fail-safe response System start |
| Module parameters | Channel alarms bundling Undervoltage diagnostics Channel alarms for undervoltage Process value representation of analogue modules |
| Configuration support | Control unit CDSB CODESYS V3 |
| Additional functions | CODESYS V3 |
| CPU data | 512 MB RAM Dual Core 766 MHz |
| storage medium | Micro SD <= 32 GB USB memory stick <= 32 GB |
| Power supply, function | Electronics and sensors |
| Power supply, connection type | Terminal strip |
| power supply, connection system | Spring-loaded terminal |
| Power supply, connection pattern | 00995847 |
| Power supply, number of pins/wires | 4 |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25% |
| Power supply, conductor diameter | 0.2 mm² ... 1.5 mm² |
| Power supply, note on conductor diameter | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves |
| Max. power supply | 8 A |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 150 mA |
| Power failure bridging | 20 ms |
| Reverse polarity protection | 24 V sensor supply against 0 V sensor supply |
| USB-interface | USB 2.0 |
| Programming software | CODESYS provided by Festo |
| Program memory | 100 MB user program |
| Processing time | Approx. 200 µs/1 k instruction |
| Function modules | And others Read CPX-E module diagnostics CPX-E diagnostic status Copy CPX-E diagnostic trace |
| Buffering time real-time clock | 3 Weeks |
| Flag | 120 kB retentive data CODESYS variable concept |
| Isolation channel - internal bus | yes |
| Manufacturer Nr. | CPX-E-CEC-C1-EP |
|---|---|
| Manufacturer | Festo |
| GPSR manufacturer information | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| EAN | 4052568418083 |
| Weight | 0.400000 |
| HS-Code | 85371091 |
| Article authenticity | Original product |
| Condition of article | New |
Customers Who Bought This Item Also Bought










