| Dimensions (W x L x H) | 18.9 x 76.6 x 124.3 mm |
| Grid dimension | 18.9 mm |
| Type of mounting | With H-rail |
| Product weight | 96 g |
| Mounting position | Vertical Horizontal |
| Ambient temperature | -5 °C ... 50 °C |
| Note on ambient temperature | -5 - 60°C for vertical installation |
| Storage temperature | -20 °C ... 70 °C |
| Relative air humidity | 95 % Non-condensing |
| Degree of protection | IP20 |
| Corrosion resistance class CRC | 0 - No corrosion stress |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Max. cable length | 30 m inputs Shielded |
| LABS (PWIS) conformity | VDMA24364 zone III |
| CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive |
| CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions |
| KC mark | KC-EMV |
| Approval | RCM trademark c UL us listed (OL) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS-compliant |
| Material housing | PA |
| Material screws | Galvanised steel |
| Diagnostics via LED | Errors per channel Errors per module |
| Diagnostics via bus | Wire break Short circuit/overload in sensor supply Parameter errors Parameterisation error Overload at analogue inputs Upper limit value violated Overflow/underflow Lower limit value not observed |
| Max. address volume, inputs | 8 Byte |
| Module parameters | Data format, analogue inputs Short circuit diagnostics for sensor supply Parameterisation error diagnostics Diagnostics of overload at analogue inputs Limit monitoring hysteresis Deactivate sensor supply Behaviour after overload on analogue inputs Behaviour after short circuit/overload |
| Channel parameters | Wire break diagnostics Parameter error diagnostics Underflow/overflow diagnostics Upper limit diagnostics Lower limit diagnostics Smoothing factor Signal range per channel Lower/upper limits |
| Internal cycle time | <= 500 µs |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25% |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 70 mA |
| Power failure bridging | 10 ms |
| Reverse polarity protection | 24 V sensor supply against 0 V sensor supply |
| Electrical connection input, function | Analogue input |
| Electrical connection input, connection type | 4x terminal strip |
| Electrical connection input, connector system | Spring-loaded terminal |
| Electrical connection input, number of connections/cores | 4 |
| Electrical connection input, connection pattern | 00995841 |
| Electrical connection for input, conductor cross section | 0.2 mm² ... 1.5 mm² |
| Electrical connection for input, note on conductor cross section | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves |
| Electrical connection for input 2, function | Functional earth |
| Electrical connection for input 2, connection type | Terminal strip |
| Electrical connection for input 2, connection technology | Spring-loaded terminal |
| Electrical connection for input 2, number of pins/wires | 4 |
| Electrical connection for input 2, connection pattern | 00995842 |
| Electrical connection for input 2, conductor cross section | 0.2 mm² ... 1.5 mm² |
| Electrical connection for input 2, note on conductor cross section | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves |
| Number of inputs | 4 |
| Max. residual current of inputs per module | 1.4 A |
| Behaviour after end of overload of the outputs | No autom. ret. (default) Parameterisable (module by module) |
| Measured variable | Voltage Current |
| Data format | 15 bits + prefix Linear scaling |
| analog input | -10 - 10 V -20 - 20 mA -5 - 5 V 0 - 10 V 0 - 20 mA 1 - 5 V 4 - 20 mA |
| Repetition accuracy | ±0.1% at 25°C |
| Basic error limit at 25 °C | ±0.2% |
| Operating error limit related to the ambient temperature range | ±0.3% |
| Isolation channel - channel | no |
| Isolation channel - internal bus | yes |
| Fuse protection (short circuit) | Internal electronic fuse per module |
| Manufacturer Nr. | CPX-E-4AI-U-I |
|---|---|
| Manufacturer | Festo |
| GPSR manufacturer information | Festo Vertrieb GmbH&Co. KG, Festo Campus 1, DE-73734 Esslingen, festo.com |
| EAN | 4052568291136 |
| Weight | 0.120000 |
| HS-Code | 85389099 |
| Article authenticity | Original product |
| Condition of article | New |